A Lenze drive’s type code starts with its generation. E82E… is the 8200 vector inverter, E84A… the 8400, EVS93… a 9300 servo inverter, E94… a 9400, and I5…, I7…, I9… the i500, i700 and i950 drives. Generations differ in their parameters, their accessories and the software that sets them up, so the first job with a failed drive is to read which one it is.
Generations by type code
| Type code starts | Generation |
|---|---|
| E82E, E82Z | 8200 vector inverters and their modules |
| E84A | 8400 inverters (StateLine, HighLine, TopLine) |
| EVS93, EVF93, EVD93 | 9300 servo and frequency inverters |
| E94 | 9400 servo drives |
| I5, I7, I9 | i500, i700, i950 |
| MCS, MDSKS, MQA | servo and asynchronous motors |
Search by the start of the type code, for example E82EV, E84AV or EVS93, or browse all Lenze parts.
The suffix carries the version
Within a generation, the letters after the rating say more. The 8400 comes as StateLine, HighLine and TopLine with different functions, and the characters at the end of a type code set the version, the interface or the special design. A drive with the same rating and a different version letter may not accept the parameter set of the old one. Copy the whole code from the nameplate, and add the hardware and software version the plate shows.
From 9300 to i950 without rewriting the machine
The 9300 servo inverter has been in machines for decades, and the question is what to do when it fails. Lenze presented the i950 as a drive that can take its place. According to a Design Solutions report from March 2026, the i950 has identical Profibus, motor and mains interfaces and a compatibility switch, so it can emulate the 9300’s behaviour without changes to the PLC software. The existing 9300 application still has to be moved to the new drive.
That makes it a real option for a planned changeover. For a machine down today, a 9300 of the same type code with your parameter set is still the shortest way back; the move to i950 can follow at the next shutdown. Finding a replacement part lists what to compare when you do change.
Keep the parameter set
The machine’s settings live in the drive and, depending on the generation, on a plug-in memory module. If the old drive still powers up, save its parameters with the Lenze engineering software before you remove it. If it has a memory module, ask Lenze or the machine builder whether that module can move to the spare, and ask the supplier whether the spare comes with one and what is on it.
Before you order
- Copy the full type code, hardware version and software version from the nameplate.
- Note the accessories: communication and function modules, memory module, brake resistor.
- Ask what “refurbished” covered. See refurbished, surplus and used and warranty on surplus parts.
Not listed? Send a request with the nameplate photo: how requests work.