Skip to content

Reading an ABB ACS355 type code before you order a spare

ACS355-03E-05A6-4 already says what a replacement has to match. Each block of the type code explained, from the EMC filter letter to the +B063 option.
Author
Sparehawk
Reading time
3 min read
Published
  • Drives
  • Part numbers

An ABB ACS355 type code such as ACS355-03E-05A6-4 reads from left to right: series, supply phases, EMC filter setting, rated output current and supply voltage. 03 is three-phase, E means the filter is connected, 05A6 is 5.6 A and 4 is 380 to 480 V. Options follow a plus sign. Match every block, options included, and the spare takes your saved parameters.

One of the searches that brought a reader to Sparehawk’s ABB page was a complete type code: ACS355-03E-05A6-4. That string already says most of what a replacement drive has to match. Here is how to read it, block by block, and what to check before the old drive comes out of the cabinet.

What each block means

Take ACS355-03E-05A6-4 apart from the left:

  • ACS355 is the product series, ABB’s compact machinery drive.
  • 03 means a three-phase supply; 01 would mean single-phase.
  • E means the internal EMC filter is connected and 50 Hz is the default motor frequency; U means the filter is disconnected and 60 Hz is the default.
  • 05A6 is the rated output current, with the A standing for the decimal point: 5.6 A.
  • 4 is the supply voltage range, 380 to 480 V; 2 would mean 200 to 240 V.

So ACS355-03E-05A6-4 is a three-phase drive for a 400 V class supply, with a 5.6 A output and the filter connected. Choose a replacement by output current and supply, not by the motor power written on an old order: two motors of the same power can draw different currents.

E or U: a factory setting with consequences

The letter after the phase code is easy to miss and matters on site. A drive with the filter connected belongs on a grounded (TN) supply. On an IT supply, ungrounded or grounded through a high resistance, the internal filter has to be disconnected as ABB’s manual describes. If the failed drive was a U unit, or an E unit that someone converted, set up the replacement the same way before it is powered.

The default frequency follows the same letter. A 60 Hz default on a 50 Hz motor, or the reverse, shows up as the wrong speed at the first start. Enter the motor data from the motor’s own rating plate rather than trusting the default.

Option codes after the plus sign

Everything after a plus sign is an option fitted at the factory. The one seen most often on ACS355 drives is +B063, the sealed version for IP66/IP67 and UL Type 4X, built for wet and dusty places outside a cabinet. A standard unit cannot take its place. Options that plug in later, such as a fieldbus adapter, are separate parts: an FPBA-01 adapter for PROFIBUS can move from the old drive to the new one if it still works.

Before the old drive comes out

  • Photograph the rating plate and write down the full type code, options included.
  • Save the parameters to the control panel or a PC tool, if the drive still powers up.
  • Look for parameter changes noted in the machine’s documentation, in case it does not.
  • Read the fault log to find out why it stopped.

The last point decides more than the price of the spare. Our post on repairing or replacing a failed drive explains why the cause comes first.

Same code or a successor

An identical type code is the quick route: the same current, supply, filter setting and options, and the saved parameters load straight in. Search the whole code first, ACS355-03E-05A6-4 for example, and only then the series. Check the ACS355’s life-cycle status on ABB’s own pages before you stock more than one spare. ABB’s newer machinery drive is the ACS380; moving to it means a new parameter set and a check of the wiring, so plan it as a small project rather than a swap. If nobody lists the exact code, post a wanted request or send a request for quotes with the full type code.

01

Frequently asked questions

1.1

What does 05A6 mean in an ABB ACS355 type code?

The rated output current, written with the letter A in place of the decimal point: 05A6 is 5.6 A.
1.2

What is the difference between ACS355-03E and ACS355-03U?

An E unit leaves the factory with the internal EMC filter connected and a 50 Hz default; a U unit with the filter disconnected and a 60 Hz default. On an IT supply the filter must be disconnected.
1.3

Can a standard ACS355 replace one with option +B063?

No. +B063 is the sealed IP66/IP67 version for use outside a cabinet. A standard unit is an IP20 drive made to be mounted inside one.
1.4

What does the last digit of the type code mean?

The supply voltage range: 2 for 200 to 240 V, 4 for 380 to 480 V.